Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Updated screenshots based on current UGA prod settings


Panel
titleFMD Messaging Resources

ASF Messaging Guide

NAHLN Certificate from Test URL 9-20-2018


Panel

API Setup - Messaging Profile

...

(HL7 Post - Auth Token)

VetView 3.X series

Example Message Profile for ASF (HL7)

  • To report to the NAHLN: Username, Password, and Certificate

...

  • or Authentication Token are required
  • Failure Email should forward to someone who has VetView admin privileges and can monitor these messages for issues
  • The Schema Definition is not required, but if present the API will validate the message before posting it to the NAHLN website.

Image Added

Message Type: NAHLN OPU_R25 - HL7

  • MSH.3 Sending Application is your Laboratories OID. OID Registry
  • MSH.4 Sending Facility is your Laboratories Premise ID
  • MSH 5 & 6 are NAHLN's information.
  • Other values will vary depending on your lab's requirements

Image Added


Patient PV1

...

Image Removed

Role ROL3

...

Image Added

OBX 

This may not be used in your lab.

Image Added

Role ROL1

Image Added

Role ROL2

Image Added

ROL3 and ROL4 are not used in this example.

Next of Kin NK1

...

Image Added

Patient Identifier PID3

...

Image Added

Specimen SPM

...

Image Added

Specimen Settings

NALHN only allows two specimen types for

...

ASF testing. Ensure that the appropriate SNOMED code is in the specimen setup.  (Common Setup Data > Specimen Setup.)

These codes are permanent and only need to be set once per specimen. 

  • Tonsil: Tissue specimen from tonsil (specimen) Code: 811000009103
  • Whole Blood Code: 258580003

 

...

  Image Added

Test Setup - Messaging Profile

...

Messaging profile must be set up for each test in your lab system that will be reported for this disease.

Image Added

Choose the profile you had defined under the Job and Interface Setting for this test.

Image Added


  • OCR.4 When a Reference Number Authority is selected, please include a reference number in the accession header for each accession.

          Image Added

  • OBR.31 Setup up a test catalog question that is restricted to a value list of acceptable reasons for submission (defined under Laboratory Setup > Value List Setup.)

          

...

Image Added

  • OBX.5 This value should be the result name that holds the CT value in test setup

          

...

Image Added

  • OBX.8 This value should be the result name that holds the interpretation in test setup. This should be restricted to a value list with only the NAHLN approved interpretation results (NDET). 

          

...

Image Added